For more Information
please call
1-800-Belden1
General Description:
23 AWG solid bare copper conductors, bonded pair PP insulation, FRNHPO spline center member, inner
FRNHPO jacket , overall Beldfoil® Shield (100% coverage), FRNHPO jacket, FRNHPO overall jacket,
sequential footage marking every two feet.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1 18 Solid BCCS - Bare Copper Covered Steel 1.016
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 4.572
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100.000
2 Braid AL - Aluminum 60.000
3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100.000
4 Braid AL - Aluminum 60.000
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
LSZH- Low Smoke Zero Halogen
Overall Cable
Overall Nominal Diameter: 7.620 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
Bulk Cable Weight: 52.087 Kg/Km
Max. Recommended Pulling Tension: 720.608 N
Min. Bend Radius/Minor Axis: 76.200 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL2, CMG-LS
CEC/C(UL) Specification: CMG
EU Directive 2011/65/EU (ROHS II): Yes
IEEE Specification: 45
EU CE Mark: Yes
Page 1 of 3 01-30-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3092T Coax - ControlNet™ Quad Shielded Coax
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 09/16/2014
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Other Specification: ABS Type Approval Certificate 13-HS1092993
RG Type: 6/U
Flame Test
UL Flame Test: UL1685 FT4 Loading, Limited Smoke
C(UL) Flame Test: FT4
IEC Flame Test: 60332-3-22 (Category A)
IEEE Flame Test: 1202
Suitability
Sunlight Resistance: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 3093A
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
53.1522
Nominal Velocity of Propagation:
VP (%)
82
Nominal Delay:
Delay (ns/m)
4.19968
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
91.868
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
11.8116
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1 1.14835
2 1.24678
5 1.47645
10 1.93579
20 2.82166
Page 2 of 3 01-30-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3092T Coax - ControlNet™ Quad Shielded Coax