MBU100 SERIES
DC/DC CONVERTER 1W, SIP-Package
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2015/07/31 REV:6 Page 2 of 4
Output Specifications
Parameter Conditions Min. Typ. Max. Unit
Output Voltage Setting Accuracy
--- ±1.0 ±3.0 %Vnom.
Line Regulation
For Vin Change of 1% --- ±1.2 ±1.5
%
Load Regulation
Io=20% to 100%
See Model Selection Guide
Ripple & Noise 0-20 MHz Bandwidth --- 100 150 mV
P-P
Temperature Coefficient --- ±0.01 ±0.02 %/℃
Short Circuit Protection 0.5 Second Max., Automatic Recovery
General Specifications
Parameter Conditions Min. Typ. Max. Unit
I/O Isolation Voltage
60 Seconds 1000 --- --- VDC
1 Seconds 1200 --- --- VDC
I/O Isolation Resistance 500 VDC 1000 --- --- MΩ
I/O Isolation Capacitance 100KHz, 1V --- 60 100 pF
Switching Frequency 50 90 110 KHz
MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign 2,000,000 Hours
Environmental Specifications
Parameter Conditions Min. Max. Unit
Operating Ambient Temperature Range (See
Power Derating Curve)
Natural Convection -40 +85 ℃
Case Temperature --- +90 ℃
Storage Temperature Range -50 +125 ℃
Humidity (non condensing) --- 95 % rel. H
Cooling Natural Convection
Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃
Power Derating Curve
(5V Output Only) (All Other Output)
Notes
1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
3 We recommend to protect the converter by a slow blow fuse in the input supply line.
4 Other input and output voltage may be available, please contact factory.
5 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
6 Specifications are subject to change without notice.
Output Power (%)