Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
Bulk Cable Weight: 132.450 Kg/Km
Max. Recommended Pulling Tension: 827.365 N
Min. Bend Radius/Minor Axis: 101.600 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
75.463
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
137.802
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
34.4505
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
34.4505
Max. Operating Voltage - Non-UL:
Voltage
350 V RMS
Max. Recommended Current:
Current
2.8 Amps per conductor @ 25°C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
9894 0101000 1,000 FT 96.000 LB BLACK C 15 #20 PP SHLD PE
Notes:
C = CRATE REEL PUT-UP.
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9894 Multi-Conductor - Direct Burial Cable, 15 Conductors Cabled