For more Information
please call
1-800-Belden1
General Description:
18 awg stranded (7x26) .048" tinned copper conductor, polyethylene insulation, double bare copper braid
shield (95% coverage), non-contaminating PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1 18 7x26 TC - Tinned Copper 1.2192
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
PE - Polyethylene 7.239
Outer Shield
Outer Shield Material:
Layer # Type Outer Shield Material Coverage (%)
1 Braid BC - Bare Copper 95
2 Braid BC - Bare Copper 95
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVCNC - Polyvinyl Chloride Non-Contaminating
Overall Cable
Overall Nominal Diameter: 10.795 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
Non-UL Temperature Rating: 60°C
Bulk Cable Weight: 181.560 Kg/Km
Max. Recommended Pulling Tension: 1005.293 N
Min. Bend Radius/Minor Axis: 107.950 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMH
CEC/C(UL) Specification: CMH
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes