For more Information
please call
1-800-Belden1
General Description:
18 awg stranded (7x26) .048" tinned copper conductor, polyethylene insulation, double bare copper braid
shield (95% coverage), non-contaminating PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1 18 7x26 TC - Tinned Copper 1.2192
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
PE - Polyethylene 7.239
Outer Shield
Outer Shield Material:
Layer # Type Outer Shield Material Coverage (%)
1 Braid BC - Bare Copper 95
2 Braid BC - Bare Copper 95
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVCNC - Polyvinyl Chloride Non-Contaminating
Overall Cable
Overall Nominal Diameter: 10.795 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
Non-UL Temperature Rating: 60°C
Bulk Cable Weight: 181.560 Kg/Km
Max. Recommended Pulling Tension: 1005.293 N
Min. Bend Radius/Minor Axis: 107.950 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMH
CEC/C(UL) Specification: CMH
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
Page 1 of 3 01-30-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9850 Coax - 75 Ohm Coax
EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Military Specification: MIL-DTL-17, M17/77, QPL
RG Type: 216/U
Flame Test
UL Flame Test: VW-1
CSA Flame Test: FT1
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.55777
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
67.2605
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/m)
5.05274
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
20.0141
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
2.6248
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1 0.6562
10 2.2967
50 4.2653
100 6.562
200 9.5149
400 13.7802
700 19.0298
900 22.3108
1000 23.2951
Max. Operating Voltage - Non-UL:
Voltage
3700 V RMS
Put Ups and Colors:
Page 2 of 3 01-30-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
9850 Coax - 75 Ohm Coax