Part Number: IOLAN SDS16C HV
Industrial Ethernet media converter, 16 serial RJ45 interfaces, especially
suited to extreme operating conditions
Product Description
Industrial Ethernet media converter is especially suited to extreme operating conditions, e.g. the kind of conditions that are found in transformer stations in the
electricity industry.
Technical Specifications
Product description
Part Number: 942 036-301
Port type and
quantity:
16 x RS323/422/485 on RJ45 connector, 2 x 10/100/1000BaseTX Ethernet
Displays
LEDs: Power, link status; serial: data per port
More Interfaces
Power
supply/signaling
contact:
1 x terminal block, 6-pin
V.24 interface: 1 x console block
Network size - length of cable
Twisted pair (TP): 0-100 m
Serial (RS232,
RS422, RS485):
10-15 m
Power requirements
Heat dissipation: 40.9 Btu
Operating Voltage: 88-300 VDC or 85-265 VAC
Service
Protocols:
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP,
Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP, IPSEC VPN client/servers,
HTTP tunneling, DHCP Opt 81
Software
Configuration: Telnet, SSH v1 and v2, Rlogin, Auto session login, LPD, RCP printer, MOTD - Message of the day
Security:
SSH v1 and v2, SSL V3.0/TLS V1.0, SSL V2.0, SSL Server and SSL client mode capability, SSL Peer authentication, IPSec VPN : NAT Traversal, ESP authentication protocol,
Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2), Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96, Key
exchange: RSA, EDH-RSA, EDH-DSS, ADH, X.509 Certificate verification: RSA, DSA, Certificate authority (CA) list, Local database, RADIUS Authentication, Authorization and
Accounting, TACACS+ Authentication, Authorization and Accounting, LDAP, NIS, Kerberos Authentication, RSA SecureID-agent or via RADIUS Authentication, SNMP v3 Authentication
and Encryption support, IP Address filtering, Disable unused daemons, Active Directory via LDAP
Flow control: Hardware, Software, Both
Ambient conditions
Operating
temperature:
-40-+70 °C
Storage/transport
temperature:
-40-+85 °C
Relative humidity
(non-condensing):
5-95 %