Frequency [MHz] Min. Structural Return Loss (SRL)
5 - 50 MHz 23 dB
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz 0.35 dB/100ft
2 MHz 0.38 dB/100ft
5 MHz 0.45 dB/100ft
10 MHz 0.59 dB/100ft
20 MHz 0.86 dB/100ft
50 MHz 1.37 dB/100ft
100 Mhz MHz 1.97 dB/100ft
200 Mhz MHz 2.82 dB/100ft
300 MHz MHz 3.48 dB/100ft
400 Mhz MHz 4.04 dB/100ft
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.22 ns/ft 83.0 %
High Freq
Min. SRL (Structural Return Loss)
23 dB
Voltage
UL Voltage Rating
300 V RMS
Temperature Range
UL Temp Rating: 75°C
Operating Temp Range: -30°C To +75°C
Mechanical Characteristics
Bulk Cable Weight: 34 lbs/1000ft
Max Recommended Pulling Tension: 117 lbs
Min Bend Radius/Minor Axis: 3 in
Standards
NEC/(UL) Specification: CMR, CL2R, CMG
CEC/C(UL) Specification: CMG
CPR Euroclass: Eca
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU: Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Aerial: Yes - When supported by messenger wire
Suitability - Burial: No
Suitability - Hazardous Locations: No
Suitability - Indoor: Yes
Suitability - Outdoor: Yes