Recommended
Barriers
Page
1
/4
www.burkert–usa.com
_
+
24 V/DC
Umin
Imin
BARRIER
Safe Area
Hazardous Area
Recommended Barriers for Use with
EXi solenoid valve solutions
PTB EEx ia IIC T5 and T6 approved
for Europe
FM IS / I, II, III / ABCDEFG approved
for USA
Applications
Chemical industry
Pharmaceutical processing equipment
Industrial waste water treatment
Oil and gas industry
Picture showing 3 examples of
Picture showing 3 examples of
intrinsically safe valve systems
intrinsically safe valve systems
Burkert offers a wide range of intrinsically safe
solutions for use in hazardous areas. For the
power supply of these products an approved
barrier is required. This data sheet gives you
an overview of approved solutions.
Page
2
/4
Rec omme nde d
Bar rier s
List of approved barriers Technical data coil AC10 EExi
Supplier
Type
Max.
Resistance
at 55°C
Bartec
Modex 07–7311–93M6/P060
144
19–100.2801/1010
163
CEAG
SB–0728
100
SB–1728
100
6/915–7
70
7/915–7
70
2/915–7
70
4/915–7
70
5/915–7
70
LB 2112
154
FB 2112
154
Hima
F3328 (Characteristics A or C)
140
H & B
V17132–55
273
V17332–61
200
MTL
728
140
4021
154
4728
110
7028+
108
7028-
108
4025
93
5025
68
8215–DO–IS
195
P & F
KFD2–SD–Ex1.48
97
KFD2–SL–Ex1.48
97
KFD2–SD–Ex1.48.90A
97
KFD2–SL–Ex1.48.90A
97
Z 728
140
Z 828
140
Z 728.CL
140
Z 828.CL
140
KSD2–BO–Ex
173
RSD–BO–Ex4
106
VAA–2EA–G5–N/V1–Ex
203
EGA–041
–3
120
ED2–VD–Ex.2.1835
160
Phoenix Contact
Pl/Ex–SD/22/45–C
191
Steel
9351/10–16–10
163
9151/10–16–10
193
9475/12–04–21
144
9475/12–04–31
82
9475/12–
08–51
54
9651/40–16–10
233
9001/01–280–100–10
138
9001/01–252–100–14
182
Turck
MC 72–41Ex–T
157
MC 72–43Ex–T
157
Following barriers are tested for use with our EExi valves in Zone 1
Please contact your Burkert representative if your preferred barrier is not on this list.