Datasheet
Sure Cross
®
Wireless Q45 Sensors combine the best of Banner’s flexible Q45 sensor family with its reliable, field-proven,
Sure Cross wireless architecture to solve new classes of applications limited only by the user’s imagination. Containing a
variety of sensor models, a radio, and internal battery supply, this product line is truly plug and play.
The Wireless Q45 Sensor with Button and Light as a wireless node with independently
controlled push button input and a four-color LED indicator light. The push button can be
configured with DIP switches for either toggle or momentary operation; the red, yellow,
green, and blue LED indicator light outputs can be configured for solid or flashing
operation.
Available Models
• DX80N9Q45BL-RYGB
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel
protection. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry
necessary to allow its use in personnel safety applications. A sensor
failure or malfunction can cause either an energized or de-energized
sensor output condition.
Storage Mode for the Wireless Q45 Sensors
While in storage mode, the Wireless Q45 Sensor's radio does not operate. All Wireless Q45 Sensors ship from the factory
in storage mode to conserve the battery. To wake the device, press and hold the button for five seconds. To put any
Wireless Q45 Sensor into storage mode, press and hold the button for five seconds. The Wireless Q45 Sensor is in storage
mode when the LEDs stop blinking.
Button, LEDs, and DIP Switches (Button with Light Model)
1
Button
2 Red LED (flashing) indicates a radio link error with the Gateway.
3 Green LED (flashing) indicates a good radio link with the Gateway.
4 Amber LED indicates when input 1 is active. The LED is active at power up and disabled
after 15 minutes to conserve power. To enable the LED for another 15 minutes, press
button once. To disable the LED, press the button 5 times.
5 DIP Switches
DIP Switch Settings
After making any changes to any DIP switch position, reboot the Wireless Q45 Sensor by triple-clicking the button, waiting
a second, then double-clicking the button.
As shown in the image above, the DIP switches are in the OFF position. To turn a DIP switch on, push the switch toward
the battery pack. DIP switches one through four are numbered from left to right as shown above.
Sure Cross
®
Wireless Q45 Sensor - Button/
Light
Original Document
192693 Rev. A
26 January 2016