Test Report
Report No.: A001E20171120056
Date: Dec.11, 2017 Page 1 of 7
Applicant: Skylab M&C Technology Co.,Ltd
Address: 6/F, Building9, Lijincheng Scientific&Technical park,Gongye East Road, Longhua District,
Shenzhen, 518109 China
Report on the submitted sample(s) said to be:
Sample Name: WIFI Module
Sample Model: SKW72-E16
Serial Model:
SKW72-E16SKW72-E8SKW72-P8SKW72-P16
Brand: SKYLAB
Supplier: SKYLAB
Manufacturer: Skylab M&C Technology Co.,Ltd
Address: 6/F, Building9, Lijincheng Scientific&Technical park,Gongye East Road, Longhua
District, Shenzhen, 518109 China
Sample Received Date: Nov.20, 2017
Testing Period: Nov.20, 2017 to Dec.01, 2017
Test Requested:
Please refer to following page(s).
Test Method:
Please refer to following page(s).
Test Result:
Please refer to following page(s).
Tested by
Reviewed by
Approved by
Luoxiao Suhongliang, Leon Liulinwen, Lewis
Test Engineer Test Team Leader Technical Director
Test Report
Report No.: A001E20171120056 Date: Dec.11, 2017 Page 2 of 7
Test Requested: Conclusion
1.As specified by client, to determine the Pb, Cd, Hg, Cr
6+
, PBBs, PBDEs content in the
submitted sample in accordance with EU RoHS Directive 2011/65/EU(RoHS) and its
amendment directives on XRF and Chemical Method.
Pass
2. As specified by client, to determine the DBP, BBP, DEHP, DIBP content in the submitted
sample in accordance with Directive 2011/65/EU (RoHS) and its amendment directive (EU)
2015/863.
Pass
Test Methods:
A: Screening by X-ray Fluorescence Spectrometry (XRF)
:With reference to IEC 62321-3-1:2013 Ed 1.0 Screening
Lead, mercury, cadmium, total chromium and total bromine by X-ray fluorescence spectrometry
B: Chemical test:
Test Item Test Method
Measuring
Instrument
MDL
Cadmium (Cd) IEC 62321-5:2013 Ed 1.0 Section 7 ICP-OES 2 mg/kg
Lead (Pb) IEC 62321-5:2013 Ed 1.0 Section 7 ICP-OES 2 mg/kg
Mercury (Hg) IEC 62321-4:2013 Ed 1.0 Section 7 ICP-OES 2 mg/kg
Non-metal
Hexavalent Chromium (Cr
6+
)
IEC 62321-7-2:2017 Ed 1.0
UV-Vis 1 mg/kg
Metal
Hexavalent Chromium (Cr
6+
)
IEC 62321-7-1:2015 Ed 1.0 UV-Vis /
PBBs/PBDEs
IEC 62321-6:2015 Ed 1.0 GC-MS 5 mg/kg