F 052e R4 www.Aimtec.com 1
Preliminary
AM200W-NZ
DC-DC Converter
Input voltage
(VDC)
Output voltage
(V)
Isolation
(VAC)
Power
(W)
Temp. range
()
Derating
()
AM200W-NZ
AM200W-NZ
Click to
ORDER
samples
Enclosed
AM200W-NZ series provides a wide input voltage range of 300-1500VDC, power up
to 200W to meet higher demands for high-power power supply in ultra-wide and
ultra-high input voltage application, and high efficiency up to 87%, low power
consumption and more energy-saving.
AM200-NZ series have input under-voltage protection to avoid frequent restart of
system to maintain the system’s stability. Offering MTBF over 300,000h, they have
reverse input voltage protection, output short circuit, over-current and over-voltage
protection. These protections greatly reduce the probability of failure of the power
supply itself while greatly enhance the safety performance of the module power
supply and the load under abnormal working conditions.
The series offers isolation voltage up to 4000VAC and high reliability, to effectively
protect the safety of the system. They can be widely used in photovoltaic power
generation, energy storage BMS, high voltage inverter and other industries.
Features
Ultra-wide 300~1500VDC input voltage range.
Operating Temp : -40 °C to +70 °C
High I/O isolation voltage : 4000VAC
Low ripple & noise : 200mV(p-p), typ..
High reliability, Long lifespan : 300 000 hrs
Input reverse polarity and under voltage
protection, output short circuit, overcurrent and
overvoltage protection
Meets 5000m altitude requirements
Training
Press Release
Product Training Video
(click to open)
Application Notes
Coming Soon!
Applications
Power Grid
Industrial
Telecom
Instrumentation
300
1500
3.3
24
48
1000
4000
0.25
200
-40
70
105
105
55
-40
3
2000
-25
Picture coming soon
F 052e R4 www.Aimtec.com 2
Preliminary
AM200W-NZ
DC-DC Converter
Single Output
Model
Input Voltage
(VDC)
Output Voltage
(VDC)
Output Current
Max (A)
Maximum Capacitive
Load (µF)
Efficiency (%)
850VDC / Full Load
AM200W-85024SNZ
850 (300 ~ 1500)
24
8.4
5000
86
AM200W-85048SNZ
850 (300 ~ 1500)
48
4.2
2000
87
Input Specification
Parameters
Conditions
Typical
Maximum
Units
Voltage range
300 ~ 1500 VDC
850
1500
VDC
Input current
300 VDC
1200
mA
850 VDC
450
1500 VDC
200
Inrush current
850 VDC
150
A
1500 VDC
250
Input under-voltage protection
Under-voltage protection begins
265
285
VDC
Under-voltage protection release
275
295
External input fuse
15A/1500 VDC, Required
Isolation Specification
Parameters
Conditions
Typical
Maximum
Units
Tested voltage
Input / Output
Leakage current 10mA,1min
4000
VAC
Input / Case
Leakage current 5mA,1min
2000
Output / Case
Leakage current 5mA,1min
2000
Output Specification
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
0 ~ 100% load
± 2
%
Line regulation
Full load
± 1
%
Load regulation
0 ~ 100% load
± 1
%
Short circuit protection
Hiccup, continuous, self-recovery
Over current protection
hiccup, self-recovery
110 ~ 300
% of Iout
Over voltage protection
24V output model
35VDC or hiccup protection
48V output model
60VDC or hiccup protection
Hold-up time
Full load, 25
o
C
850 VDC input
5
ms
1500 VDC input
8
Start delay time*
300 ~ 1500 VDC
3
s
Temperature coefficient
± 0.02
%/
o
C
Models & Specifications