TAI-TECH
P2
5. Specification
Part Number
Inductance
L0 A(uH)
±20%
Heat Rating
Current DC
( A ) Irms.
Saturation
Current DC
(A)I sat
DCR
(mΩ)
Typ
DCR
(mΩ)
Max
Type
Typ Max Typ Max
TMPA1265SP-R10YN-D 0.10±30% 65 60 120 115 0.2 0.25
non-leadframe
TMPA1265SP-R22MN-D 0.22 53 42 112 105 0.4 0.46
non-leadframe
TMPA1265SP-R33MN-D 0.33 46 36 75 65 0.6 0.7
non-leadframe
TMPA1265SP-R68MN-D 0.68 36.5 33 55 46 1.25 1.5
non-leadframe
TMPA1265SP-1R0MN-D 1.00 33 29 45 36 1.5 1.8
non-leadframe
TMPA1265SP-1R5MN-D 1.50 29 25 35 30 2.2 2.53
non-leadframe
TMPA1265SP-1R8MN-D 1.80 27 23 31 27 3.2 3.6
leadframe
TMPA1265SP-2R2MN-D 2.20 25 21 28.5 24 3.7 4.2
leadframe
TMPA1265SP-2R7MN-D 2.70 24 20 27.5 23 4.2 5.0
leadframe
TMPA1265SP-3R3MN-D 3.30 22 19 27 22.5 5.3 6.2
leadframe
TMPA1265SP-4R7MN-D 4.70 20 17 25 21 6.8 8.0
leadframe
TMPA1265SP-5R6MN-D 5.60 18 15 23 19.5 8.3 9.8
leadframe
TMPA1265SP-6R8MN-D 6.80 16.5 14 21 18 9.8 11.3
leadframe
TMPA1265SP-8R2MN-D 82.0 15 12.5 19 17 12 13.8
leadframe
TMPA1265SP-100MN-D 10.0 13 11 17 15 13 15.8
leadframe
TMPA1265SP-150MN-D 15.0 11 9.5 13.5 12 22 26
leadframe
TMPA1265SP-220MN-D 22.0 10 8 10 9 31 35
leadframe
TMPA1265SP-270MN-D 27.0 9.5 7.2 9.0 8.0 36 45
leadframe
TMPA1265SP-330MN-D 33.0 9.0 6.5 9.0 8.0 46 55
leadframe
TMPA1265SP-470MN-D 47.0 8.0 5.7 7.6 6.8 58 67
leadframe
TMPA1265SP-680MN-D 68.0 5.8 4.8 6.0 5.0 82 100
leadframe
TMPA1265SP-820MN-D 82.0 5.0 4.0 5.0 4.2 110 132
leadframe
TMPA1265SP-101MN-D 100 5.0 3.8 5.0 4.0 140 161
leadframe
Note:
1. Test frequency : Ls : 100KHz /1.0V.
2. All test data referenced to 25℃ ambient.
3. Testing Instrument(or equ) : L: HP4284A,CH11025,CH3302,CH1320,CH1320S LCR METER / Rdc:CH16502,Agilent33420A MICRO OHMMETER.
4. Heat Rated Current (Irms) will cause the coil temperature rise approximately ΔT of 40℃
5. Saturation Current (Isat) will cause L0 to drop approximately 30%.
6. The part temperature (ambient + temp rise) should not exceed 125 under worst case operating conditions℃ .Circuit design,component,PCB trace size and
thickness,airflow and other cooling provisions all affect the part temperature. Part temperature should be verified in the end application.
7. Special inquiries besides the above common used types can be met on your requirement.