1. Active Errata Summary
These tables list all known errata for the EFM32LG and all unresolved errata in revision E of the EFM32LG.
Table 1.1. Errata History Overview
Designator Title/Problem Exists on Revision:
B C D E
ADC_E116 Offset in ADC Temperature Sensor Calibration Data — — X —
ADC_E117 TIMEBASE not wide enough X X X —
AES_E101 BYTEORDER Does Not Work in Combination with DATA-
START/XORSTART
X X X —
AES_E102 AES_STATUS_RUNNING Set One Cycle Late With BYTEOR-
DER Set
X X X —
BU_E101 Backup Power Increased Power Consumtion X — — —
BU_E102 EM4 GPIO Retention in Backup Mode X — — —
BU_E104 EM4 with Backup BODs X — — —
BU_E105 LFXO Missing Cycles During IOVDD Ramping X X X X
BU_E106 Current Leakage in Backup Mode — — X —
BURTC_E101 BURTC LPMODE Entry X X X —
BURTC_E102 BURTC_CNT Read Error X X X —
CMU_E108 LFxCLKEN Write X — — —
CMU_E110 LFXO Phase Shift X — — —
CMU_E111 LFXO Configuration Incorrect X X — —
CMU_E112 LFXO Boost Buffer Current Setting — — X —
CMU_E113 LFXO Startup at High Temperature — — X —
CMU_E114 Device Not Waking Up From EM2 When Using Prescaled Non-
HFRCO Oscillator as HFCLK
X X X X
CUR_E103 Increased EM2 Current — X — —
CUR_E104 Increased Current on AVDD2 (USB) X X — —
CUR_E105 Increased Current on AVDD2 (No USB) X X — —
DAC_E109 DAC Output Drift Over Lifetime X X X X
DI_E101 Flash Page Size X X X —
DMA_E101 EM2 with WFE and DMA X X X —
DMA_E102 2D Copy Corrupted by Ping-Pong or Scatter-Gather Operation
on Another Channel
X X X X
EBI_E101 EBI Masking Functionality X — — —
EBI_E102 EBI Access Fails X — — —
EBI_E103 Page Mode Read in D16A16ALE Mode X X X —
EMU_E105 Debug Unavailable During DMA Processing from EM2 X — — —
EMU_E107 Interrupts During EM2 Entry X X X X
EFM32LG Errata
Active Errata Summary
silabs.com | Building a more connected world. Rev. 1.3 | 2