以下測試樣品係由申請廠商所提供及確認 (The following sample(s) was/were submitted and identified by/on
behalf of the applicant as)
收件日期(Sample Receiving Date)
測試需求(Test Requested)
THIN FILM CURRENT SENSING CHIP RESISTOR
TCS SERIES
樣品名稱(Sample Description)
號碼(No.) : CE/2018/14944 日期(Date) : 2018/01/29
VIKING TECH CORPORATION
Test Report
新竹縣湖口鄉新竹工業區光復北路70號
樣品型號(Style/Item No.)
光頡科技股份有限公 (VIKING TECH CORPORATION)
其他測試項目請見下一頁 . (Please refer to next pages for the other item(s).)
依據客戶指定,參考RoHS 2011/65/EU Annex II及其修訂指令(EU) 2015/863測試鎘、鉛、汞、六價鉻、多溴聯苯、多溴聯苯
醚, DBP, BBP, DEHP, DIBP. (As specified by client, with reference to RoHS 2011/65/EU Annex II and amending
Directive (EU) 2015/863 to determine Cadmium, Lead, Mercury, Cr(VI), PBBs, PBDEs, DBP, BBP, DEHP, DIBP
contents in the submitted sample(s).)
請參閱下一頁 (Please refer to following pages).
根據客戶所提供的樣品,其鎘、鉛、汞、六價鉻、多溴聯苯、多溴聯苯醚, DBP, BBP, DEHP, DIBP
的測試結果符合RoHS指令暨(EU) 2015/863之限值要求. (Based on the performed tests on
submitted sample(s), the test results of Cadmium, Lead, Mercury, Cr(VI), PBBs, PBDEs,
DBP, BBP, DEHP, DIBP comply with the limits as set by RoHS and amending Directive (EU)
2015/863.)
NO. 70, KUANFU N. ROAD, HSIN CHU INDUSTRIAL PARK, HUKOU, HSIN CHU HSIEN 303, TAIWAN
2018/01/22
2018/01/22 TO 2018/01/29
測試結果(Test Results)
測試期間(Testing Period)
結論(Conclusion)
光頡科技股份有限公司 *CE/2018/14944*
送樣廠商(Sample Submitted By)
25, Wu Chyuan 7th Road, New Taipei Industrial Park, Wu Ku District, New Taipei City, Taiwan /新北市五股區新北產業園區五權七路25
t+886 (02)2299 3939 f+886 (02)2299 3237 www.sgs.tw
Member of the SGS Group
SGS Taiwan Ltd. 台灣檢驗科技股份有限公司
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Termse-Document.aspx. Attention is
drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s
findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties
to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the
Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested.
For Question
Please Contact with SGS
www.sgs.com.tw
Signature Not Verified
頁數(Page): 2 of 13
號碼(No.) : CE/2018/14944 日期(Date) : 2018/01/29
VIKING TECH CORPORATION
Test Report
新竹縣湖口鄉新竹工業區光復北路70號
NO. 70, KUANFU N. ROAD, HSIN CHU INDUSTRIAL PARK, HUKOU, HSIN CHU HSIEN 303, TAIWAN
光頡科技股份有限公司 *CE/2018/14944*
No.1
2 n.d. 100
2 189 1000
2 n.d. 1000
8 n.d. 1000
5 n.d. -參考IEC 62321 (2008),以氣相層析/
質譜儀檢測. / With reference to
IEC 62321 (2008). Analysis was
performed by GC/MS.
參考IEC 62321-4 (2013),以感應耦合
電漿原子發射光譜儀檢測. / With
reference to IEC 62321-4 (2013)
and performed by ICP-AES.
THIN FILM CURRENT SENSING CHIP RESISTOR
測試結果(Test Results)
測試部位(PART NAME)No.1
試方
(Method)
參考IEC 62321-5 (2013),以感應耦合
電漿原子發射光譜儀檢測. / With
reference to IEC 62321-5 (2013)
and performed by ICP-AES.
/ Cadmium (Cd) mg/kg
結果
(Result)
測試
(Test Items)
單位
(Unit)
方法
極限
(MDL)
限值
(Limit)
參考IEC 62321-5 (2013),以感應耦合
電漿原子發射光譜儀檢測. / With
reference to IEC 62321-5 (2013)
and performed by ICP-AES.
/ Mercury (Hg) mg/kg
六價鉻 / Hexavalent Chromium Cr(VI)
(◆)
/ Lead (Pb) mg/kg
參考IEC 62321-7-2 (2017),以UV-VIS
檢測;參考IEC 62321-5 (2013),以
ICP-AES檢測. / With reference to
IEC 62321-7-2 (2017) and performed
by UV-VIS.;With reference to IEC
62321-5 (2013) and performed by
ICP-AES.
mg/kg
六溴環十二烷及所有主要被辨別出的異構
/ Hexabromocyclododecane (HBCDD)
and all major diastereoisomers
identified (α- HBCDD, β- HBCDD,
γ- HBCDD) (CAS No.: 25637-99-4 and
3194-55-6 (134237-51-7, 134237-50-6,
134237-52-8))
mg/kg
25, Wu Chyuan 7th Road, New Taipei Industrial Park, Wu Ku District, New Taipei City, Taiwan /新北市五股���新北產業園區五權七路25
t+886 (02)2299 3939 f+886 (02)2299 3237 www.sgs.tw
Member of the SGS Group
SGS Taiwan Ltd. 台灣檢驗科技股份有限公司
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Termse-Document.aspx. Attention is
drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s
findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties