Protectowire Linear Heat Detector DATA SHEET
■Protectowire Linear Heat Detector is a proprietary cable that detects heat anywhere along its length. The sensor cable is comprised of two steel conductors individually insulated with a heat sensitive polymer. The insulated conductors are twisted together to impose a spring pressure between them, then wrapped with a protective tape and finished with an outer jacket suitable for the environment in which the detector will be installed.
■Protectowire is a fixed temperature digital sensor and is therefore capable of initiating an alarm once its rated activation temperature is reached. At the rated temperature, the heat sensitive polymer insulation yields to the pressure upon it, permitting the inner conductors to move into contact with each other thereby initiating an alarm signal. This action takes place at the first heated point anywhere along the detector’s length. It does not require a specific length to be heated in order to initiate an alarm, nor system calibration to compensate for changes in the installed ambient temperature. Protectowire Linear Heat Detector provides the advantages of line coverage with point sensitivity.
●Features
■Line coverage... continuous sensitivity.
■Eight alarm temperature ratings.
■The ability to withstand severe environmental conditions.
■Approval for use hazardous locations when used with required equipment.
■Ease of installation, testing, and splicing.
■Compatibility with other initiation devices on same circuit.
■Listed for spacing up to 50 ft. (15.2m).
| 世强硬创平台www.sekorm.com | |
| 世强硬创平台电子商城www.sekorm.com/supply/ | |
| 世强硬创平台www.sekorm.com | |
| 世强硬创平台www.sekorm.com |
- +1 Like
- Add to Favorites
All reproduced articles on this site are for the purpose of conveying more information and clearly indicate the source. If media or individuals who do not want to be reproduced can contact us, which will be deleted.
Recommend
PIM-230 Interface Module Protetowire PHSC & PLR Linear Heat Detector Interface Module DATA SHEET
2024/7/24 - Datasheet
PROTETOWIRE PHSC & PLR LINEAR HEAT DETECTOR INTERFACE MODULE,检测控制模块,INTERFACE MODULE,DETECTION CONTROL MODULE,接口模块,PROTETOWIRE PHSC&PLR线型感温探测器接口模块,PIM-230,PIM-230E
Protectowire PLR-500-XCR Line Heat Detector DATA SHEET
2022/5/25 - Datasheet
FIXED TEMPERATURE DIGITAL SENSOR,定温数字传感器,线热探测器,PROTECTOWIRE LINEAR HEAT DETECTOR,LINE HEAT DETECTOR,保护线线型感温探测器,PLR-500-XCR
PIM-530 Series Protectowire Linear Heat Detector Interface Module DATA SHEET
2022/12/10 - Datasheet
PROTECTOWIRE LINEAR HEAT DETECTOR INTERFACE MODULE,PROTECTOWIRE线型感温探测器接口模块,检测控制模块,DETECTION CONTROL MODULE,接口模块,INTERFACE MODULE,PIM-530E,PIM-530 SERIES,PIM-530E-I,PIM-530
SRP-4x4 Fire Alarm/Releasing Control Panel
2023/9/14 - Datasheet
FOUR ZONE CONTROL PANEL,火灾报警/释放控制面板,FIRE ALARM/RELEASING CONTROL PANEL,四区控制面板,UL LISTED AND FM APPROVED, FIRE ALARM/RELEASING CONTROL PANEL,UL认证和FM认证,火灾报警/释放控制面板,AM-91-2,RB-4,SRP-4X4,SRP-4X4M
When should I consider using arc-resistant switchgear?
2024-07-09 - Technical Q&A Arc-resistant switchgear should be considered whenever operator safety is a concern. Arc-resistant switchgear channels arc energy inside the equipment, away from personnel, and out the top of the switchgear.
What standards apply to arc-resistant switchgear?
2024-06-28 - Technical Q&A Arc-resistant switchgear meets or exceeds the standard of ANSI C37.20.7, in addition to all other ANSI/IEEE standards for low-voltage metal-enclosed switchgear, including ULT 1558 and CSAT.
What is the premium for arc-resistant switchgear over traditional switchgear?
2024-07-09 - Technical Q&A The premium will depend on the level of protection desired— Type 2B, with plenum or without plenum. Additionally, layout of the switchgear could increase or decrease the premium based on the number of breakers per structure. Please contact your Eaton field sales engineer or Asheville division sales engineer for pricing of arc-resistant switchgear.
What are the required clearances around arc-resistant switchgear?
2024-07-09 - Technical Q&A Arc-resistant switchgear has the same clearances as defined by NECT for traditional Magnum DS switchgear. No additional front or rear clearances are required. There is also a requirement for a minimum 10 feet (3.05 meters) floor-to-ceiling height for arc-resistant switchgear.
What are the required clearances around arc-resistant switchgear?
2024-06-28 - Technical Q&A Arc-resistant switchgear has the same clearances as defined by NECT for traditional Magnum DS switchgear. No additional front or rear clearances are required. There is also a requirement for a minimum 10 feet (3.05 meters) floor-to-ceiling height for arc-resistant switchgear.
Does the use of arc-resistant switchgear change the footprint of low-voltage switchgear, or does it change the supports at the base?
2024-07-09 - Technical Q&A There are no footprint changes to our standard structure sizes using arc-resistant switchgear. There are also no changes to how the switchgear is anchored. However, for layout purposes, arc-resistant switchgear must be 66 inches (1676.4 millimeters) wide minimum due to the volume of space needed to handle the arc pressure inside the gear.
Does the use of arc-resistant switchgear preclude the use of a top-of-switchgear rail-mounted lifting mechanism?
2024-06-28 - Technical Q&A Our arc-resistant switchgear allows the use of our standard top-of-switchgear lifting mechanism (Cat No. 8651C91G01)
What standards apply to arc-resistant switchgear?
2024-07-09 - Technical Q&A Arc-resistant switchgear meets or exceeds the standard of ANSI C37.20.7, in addition to all other ANSI/IEEE standards for low-voltage metal-enclosed switchgear, including ULT 1558 and CSAT.
Does Eaton publish installation guidelines for the installing contractor for arc-resistant switchgear?
2024-07-09 - Technical Q&A An addendum to the existing Magnum DS installation manual is available for arc-resistant switchgear: IB01901001E.
Does the use of arc-resistant switchgear preclude the use of a top-of-switchgear rail-mounted lifting mechanism?
2024-07-09 - Technical Q&A Our arc-resistant switchgear allows the use of our standard top-of-switchgear lifting mechanism (Cat No. 8651C91G01)
Electronic Mall
No such product available
1,000+ manufacturers millions of in-stock SKUsOrdering / RFQ